
Overview
XLPE (cross-linked polyethylene) insulated power cable is the standard choice for low-voltage power distribution in utilities, construction and industrial applications — offering excellent electrical performance, good thermal capacity and long service life.
Huanghe Cable manufactures 0.6/1kV XLPE power cable in a full range of configurations: 3-core, 4-core and 5-core, in copper or aluminium conductor, with unarmoured, steel-tape-armoured (YJV22 / YJV23) or steel-wire-armoured (YJV32) options to suit buried, conduit and exposed installations.
Our 0.6/1kV XLPE power cable is produced to GB/T 12706.1-2020 and covered by our internationally recognised CB certification to IEC 60502-1:2021 (Certificates CN74209 & CN74210) — verifiable compliance you can present to buyers, inspectors and procurement teams with confidence.
Each batch undergoes routine testing of conductor resistance, insulation and voltage withstand before dispatch, so you can rely on consistent quality shipment after shipment.
Available for export to markets across Africa, Southeast Asia and Central Asia, our cable is your dependable, certification-backed choice for low-voltage power distribution. Request a quote with your conductor type, core count and size, and we'll respond fast.
Technical Specifications
Real parameters — confirm against your order| Model | YJV / YJLV (unarmoured), YJV22 (steel-tape STA, PVC sheath), YJV23 (steel-tape STA, PE sheath), YJV32 (steel-wire SWA) |
|---|---|
| Rated voltage | 0.6/1 kV |
| Conductor | Copper or aluminium, Class 1/2 |
| Cores | 1 / 2 / 3 / 3+1 / 3+2 / 4 / 5 core |
| Cross-section | 1.5 – 400 mm² multicore; single-core up to 1000 mm² on request |
| Insulation | XLPE (cross-linked polyethylene) |
| Armour | None / steel tape (STA) / steel wire (SWA) |
| Flame-retardant class | ZRA / ZRB / ZRC per IEC 60332-3 style bunched-cable test (7 / 3.5 / 1.5 L combustible material per metre; char height ≤ 2.5 m) — state the class when ordering |
| Conductor resistance at 20 °C (Cu) | 1.5 mm² = 12.1 · 2.5 = 7.41 · 4 = 4.61 · 6 = 3.08 · 10 = 1.83 · 16 = 1.15 · 25 = 0.727 · 50 = 0.387 · 95 = 0.193 · 150 = 0.124 · 240 = 0.0754 · 400 = 0.047 · 630 = 0.0283 · 1000 mm² = 0.0176 Ω/km (aluminium ≈ 1.64×) |
| Temperature | 90 °C continuous conductor; 250 °C max. short-circuit (5 s); routine voltage test 3.5 kV / 5 min |
| Standard | GB/T 12706.1-2020 |
| Certificate | CB to IEC 60502-1:2021 (CN74209 & CN74210), CCC, ISO 9001/14001/45001 |
| Packing | Export wooden/steel drums, 500–1000 m/drum |
| MOQ | 500 m (project & sample accepted) |
| Lead time | 7–35 days ex-works (by specification & quantity) |
Specifications are indicative and produced to your project standard. Type-test reports available on request.
Applications
Application Guides
How this cable family is specified in real projects — voltage class, sheath and testing differ by application.
Power & Substations
MV cables for power plants, solar farms and grid substations up to 26/35 kV (we do not offer 110 kV and above).
Buildings & Fire Safety
Fire-rated BTTZ and NH cables for high-rises, malls, hospitals and data centres.
Industrial Plants
Control, instrumentation and flexible power cables for factories and processing lines.
Mining & Tunnelling
Tough rubber and armoured cables for underground mines, conveyors and tunnelling.
Rural Electrification
ACSR/AAAC conductors and ABC for village grids and long-span distribution.
Solar & Wind
UV-resistant DC solar and MV array cables for PV plants and wind farms.
Request a Quote
Tell us your size, voltage, core count, quantity and destination — our export team replies within one working day.
