Fire-survival and THHN-class wiring for high-rise and industrial projects
The Philippine market has an unusual split. Life-safety circuits in high-rises and data centres are specified around fire survival, while general building wiring is overwhelmingly THHN / THWN-2 because that is what the Philippine Electrical Code and local distributors work in. We manufacture both sides of that split: mineral insulated and mica-taped fire-resistant cable for the life-safety risers, and BV/BVR building wire that serves as the equivalent of THHN for projects that accept an IEC-based construction — with THHN/THWN-2 quoted on request where the specification is strict.
Market conditions that shape the order
Demand driver
High-rise residential and office construction in Metro Manila, Cebu and Davao; data-centre build-out; island grid projects under the national electrification programme.
Wiring convention
THHN / THWN-2 (600 V, 90 °C dry / 75 °C wet, nylon-coated, UL 83) dominates branch-circuit wiring. IEC-based BV/BVR is accepted on many projects, but the submittal has to make the equivalence explicit.
Climate constraint
Typhoon belt with 20+ storms a year, humidity near saturation in the rainy season, and salt exposure on coastal and island sites. Coastal corrosion of armour and terminations is a recurring failure mode.
Procurement pattern
Import is usually handled by a local distributor or trading company that holds the product registration; the project contractor approves the technical submittal. Expect the submittal — not the price — to decide the order.
Certificates and registrations
Each line below states who actually holds the document. We do not print a national mark we have not been granted; where local registration is mandatory, it is applied for by the importer of record and we supply the factory file it depends on.
The Philippine Standard mark for locally sold wires and cables is applied for by the importer of record. We do not hold a PS licence. We supply the factory test reports, construction data and CB certificate that support the application.
Shipments covered by the BPS scheme are cleared against an ICC obtained by the importer. Drum marking and batch identification are prepared to match the ICC application.
CN74209 / CN74210. Valid evidence for LV XLPE constructions; it does not extend to MV or to fire-survival performance.
Fire-survival claims are only made against a test report for the specific construction. Reports are issued per order; the required category and standard must be stated at enquiry.
What we supply for this market
BTTZ Rigid Mineral Insulated Cable
No polymer in the construction — the reference answer for fire pumps, pressurisation fans and lift rescue circuits.
NH-YJV Fire-Resistant Power Cable
Mica-taped XLPE feeder for long fire-survival power routes where rigid MI is impractical.
Building Wire (BV / BVR)
Serves as the IEC-side equivalent for THHN-class branch wiring; THHN/THWN-2 construction quoted on request.
XLPE Power Cable 0.6/1 kV
Main and sub-main distribution in towers and plants, CB-certified for the 0.6/1 kV range.
Typical buying segments
Shipping and lead time
Ports served
Manila (North & South Harbor) · Batangas · Cebu · Subic
Lead time
7–35 days ex-works by specification and quantity (BTTZ and NH constructions toward the upper end).
Terms
FOB or CIF Manila / Cebu; terms confirmed per order.
Typhoon season (roughly July to October) affects port congestion and vessel schedules. We build buffer into promised delivery dates for shipments booked in that window rather than quoting the ex-works date as if it were the arrival date.
Reference shipments
Client names and commercial quantities are published only with the customer’s written permission.
PS Mark and ICC are importer-side registrations. We state clearly on every submittal which certificates are ours and which belong to the importer. Regulatory and standards references are general and current-edition details should be confirmed with your customs broker or consultant before tender submission.