Fire / Mineral

NH-YJV Fire-Resistant Power Cable

Request a Quote
NH fire-resistant power cable cross-section with mica tape barrier

Overview

When the fire-survival circuit is a power feeder — a fire pump motor, a smoke-extraction fan board — the answer is usually NH-YJV: an ordinary XLPE power cable construction with one decisive addition, a mica-glass tape wound directly on the conductor.

This page covers the NH grade only. If the project also specifies flame-retardant (ZR) or low-smoke halogen-free (WDZ) grades, or needs medium voltage, start from the ZR / WDZ range overview instead.

  • Mica-glass tape barrier on each conductor: the inorganic mica retains dielectric separation while the XLPE around it decomposes in the fire
  • Rated 0.6/1 kV; full size range from 1.5 mm² control sizes up to 400 mm² power feeders; armoured (NH-YJV22) and aluminium-conductor variants available
  • Maintains circuit integrity through the standard fire temperature curve; pairs with flame-retardant sheath options
  • Manufactured to comply with GB/T 19666 (fire-resistant cable and test methodology); manufactured to your specified standard, with the IEC 60331 fire-resistance type-test report issued with the order
  • The economical fire-survival answer for long power routes where rigid MI is not practical

Technical Specifications

Real parameters — confirm against your order
TypeNH-YJV / NH-YJV22 (armoured) fire-resistant power cable
Rated voltage0.6/1 kV
ConductorCopper (aluminium variants available)
InsulationXLPE + mica-glass fire barrier tape on conductor
Fire behaviourCircuit integrity through standard fire curve
Sizes1.5 – 400 mm² (per construction table)
StandardGB/T 19666; customer specs on request
CertificateISO 9001/14001/45001; batch test records
Lead time7–35 days ex-works (by specification & quantity)

Specifications are indicative and produced to your project standard. Type-test reports available on request.

Applications

Fire pump & sprinkler pump feeders
Smoke extraction fan feeders
Emergency power distribution
Generator to ATS circuits

Application Guides

How this cable family is specified in real projects — voltage class, sheath and testing differ by application.

Request a Quote

Tell us your size, voltage, core count, quantity and destination — our export team replies within one working day.

PDF, Word, Excel, CSV, ZIP or images — up to 5 files, 10 MB each

Your inquiry goes directly to Betty, Overseas Sales. We reply within 1 business day.

We use the details you submit — company, contact, destination country and the requirement you describe — only to prepare your quotation and technical documents, and to follow up on this enquiry. We do not sell or share them for marketing. See our Privacy Policy for retention and deletion.