Overview
Medium-voltage power cable carries power from substations to industrial sites, large facilities and utilities. Because MV is specified as a Uo/U pair rather than a single number, always quote the rating exactly as your network requires — 3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV, 18/30kV or 26/35kV are the ratings we are most often asked for. Buyers in the Middle East, Southeast Asia and other IEC/British-standard markets often specify the UK-style equivalents 6.35/11kV, 12.7/22kV and 19/33kV — quote us either way and we map it to the right construction.
Huanghe Cable manufactures MV XLPE cable with the construction and screening required for reliable performance at MV levels, available in armoured and unarmoured configurations to suit your installation and protection needs.
Our MV cable is insulated with cross-linked polyethylene (XLPE) for excellent dielectric strength, long service life and thermal stability, with proper semiconductive and metallic screens to manage the electrical field and provide a clear path for fault current.
We produce to recognised technical standards, and our technical team supports you with selection, armouring and specification advice so the cable matches your project's real operating conditions.
For MV projects requiring specific national standards, we manufacture on request with type-test reports available on demand. Send us your voltage, core count, size and installation method, and we'll provide a competitive quotation backed by real production capability.
Technical Specifications
Real parameters — confirm against your order| Rated voltage (Uo/U) | 3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV, 18/30 kV, 26/35 kV (Um up to 40.5 kV). UK/Middle East style equivalents 6.35/11, 12.7/22, 19/33 kV on request |
|---|---|
| Conductor | Copper or aluminium, compacted Class 2 |
| Cores | Single-core or 3-core |
| Cross-section | 25 – 630 mm² |
| Insulation | XLPE |
| Screen | Conductor & insulation semi-conductive layers + metallic copper screen (tape for 3-core, wire with copper tape for single-core) |
| Armour | Unarmoured, steel-tape (STA) or steel-wire (SWA) |
| Standard | GB/T 12706.2-2020 / GB/T 12706.3-2020; IEC 60502-2 construction |
| Certificate | No CB certificate for MV — our CB certificates cover IEC 60502-1:2021, 0.6/1kV only. MV is supplied with ISO 9001/14001/45001 management systems and type-test reports on request |
| Tests | Partial discharge & HV routine test; type tests on request |
| Packing | Export steel/wooden drums |
| Lead time | 7–35 days ex-works (by specification & quantity) |
Specifications are indicative and produced to your project standard. Type-test reports available on request.
Applications
Application Guides
How this cable family is specified in real projects — voltage class, sheath and testing differ by application.
Power & Substations
MV cables for power plants, solar farms and grid substations up to 26/35 kV (we do not offer 110 kV and above).
Buildings & Fire Safety
Fire-rated BTTZ and NH cables for high-rises, malls, hospitals and data centres.
Industrial Plants
Control, instrumentation and flexible power cables for factories and processing lines.
Mining & Tunnelling
Tough rubber and armoured cables for underground mines, conveyors and tunnelling.
Rural Electrification
ACSR/AAAC conductors and ABC for village grids and long-span distribution.
Solar & Wind
UV-resistant DC solar and MV array cables for PV plants and wind farms.
Request a Quote
Tell us your size, voltage, core count, quantity and destination — our export team replies within one working day.